Page view 10
NV-P2100 Wiring Diagram
11
R
L
SENSITIVITY
OdBV = 1.0RMS
-12
+6
0
LEFT
+6
-12
RIGHT
0
AUDIO
INPUT
2
INPUT
OUTPUT
CONTROL
SPEAKER
MODEL NV-P2100
HIGH EFFICIENCY 200 WATT
STEREO AMPLIFIER
NuVo Technologies Cincinnati Ohio. USA
120V
60HZ
WATTS
250
UNIT
ON
+12VDC
100mA
VOLTAGE
TRIGGER
3-30 VOLTS
AC OR DC
ON/OFF SWITCH
AUDIO AC/DC
POWER
MODE
OUTPUT POWER
8 OHM: 70W X 2
4 OHM: 100W X 2
CONTROL
USE ONLY WITH 250V FUSE
USE ONLY WITH 250V FUSE
120V 60Hz 300W
MODE L NV-E6M
SI X SOURCE SIX ZONE
AUDI O DIST RI BUT IONSYST EM
KUST OM I NC. CI NCI NNATI , OH USA
LINE OUT
L
LINE OUT / SPEAK E R
LINE OUT LINE OUT LINE OUT LINE OUT LINE OUT
ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6
20W/8 OHM X2 20W/8 OHM X2 20W/8 OHM X2 20W/8 OHM X2 20W/8 OHM X2 20W/8 OHM X2
RLRLRLRLRLR
LEFT
-+
RIGHT
-+
LEFT
-+
RIGHT
-+
LEFT
-+
RIGHT
-+
LEFT
-+
RIGHT
-+
LEFT
-+
RIGHT
-+
LEFT
-+
RIGHT
-+
0215
IR EMITTER OUTPUTS
+12V OUTPUT PULSE
123456SUM
AUDIO OUTPUT
CONNECT TONV-E6X
ODD NUMBERED OUTPUTS ARE IDENTICAL ( TIED TOGETHER)
EVEN NU MBERE D OUT PUTS ARE I DENTI CAL ( TIED TOGE THER)
REFER TO MANUAL
0123
DIAGNO STI C
CONTROL
-INPUT- -OUTPUT-
MUTE UNITON
+12V GN.O. G
1
23456
INPUT SOURCES
L
R
DIGITAL OUTPUT
CONNECT TO
NV-E6X
NETWORK
CONNECTTO
NV-EZP
The NuVo P2100 has the ability to be triggered by an incoming audio signal, or by the presence of a voltage as shown in the
diagram with the NuVo Essentia system.
The variable line-out of the NuVo Essentia amplifier allow the volume to be controlled by the audio systems keypads. The best
sensitivity trim setting for this is +6.